Proline Promag 300 Modbus RS485 Modbus RS485 Register Information
Endress+Hauser 261
Navigation: Expert → Diagnostics → Simulation
Parameter Register Data type Access Selection / User entry / User interface → 
Curr.inp 1 to n sim. (1608–1 to n) 1: 6127
2: 6128
3: 6129
Integer Read / Write 0 = Off
1 = On
204
Value curr.inp 1 to n (1609–1 to n) 1: 6139 to 6140
2: 6141 to 6142
3: 6143 to 6144
Float Read / Write 0 to 22.5 mA 205
Curr.out. 1 to n sim. (0354–1 to n) 1: 5939
2: 5940
3: 5941
Integer Read / Write 0 = Off
1 = On
205
Value curr.out 1 to n (0355–1 to n) 1: 5995 to 5996
2: 5997 to 5998
3: 5999 to 6000
Float Read / Write 3.59 to 22.5 mA 205
FreqOutputSim 1 to n (0472–1 to n) 1: 6203
2: 6204
3: 6205
Integer Read / Write 0 = Off
1 = On
206
Freq value 1 to n (0473–1 to n) 1: 6207 to 6208
2: 6209 to 6210
3: 6211 to 6212
Float Read / Write 0.0 to 12 500.0 Hz 206
Puls.outp.sim. 1 to n (0458–1 to n) 1: 6215
2: 6216
3: 6217
Integer Read / Write 0 = Off
1 = Down-count. val.
2 = Fixed value
207
Pulse value 1 to n (0459–1 to n) 1: 6219
2: 6220
3: 6221
Integer Read / Write 0 to 65 535 207
Switch sim. 1 to n (0462–1 to n) 1: 6223
2: 6224
3: 6225
Integer Read / Write 0 = Off
1 = On
207
Switch status 1 to n (0463–1 to n) 1: 6227
2: 6228
3: 6229
Integer Read / Write 1 = Open
6 = Closed
208
Relay out. 1 to n sim (0802–1 to n) 1: 7523
2: 7524
3: 7525
Integer Read / Write 0 = Off
1 = On
208
Switch status 1 to n (0803–1 to n) 1: 8239
2: 8240
3: 8241
Integer Read / Write 1 = Open
6 = Closed
209
Puls.outp.sim. (0988) 5957 Integer Read / Write 0 = Off
1 = Down-count. val.
2 = Fixed value
209
Pulse value (0989) 5973 Integer Read / Write 0 to 65 535 210
Dev. alarm sim. (0654) 6812 Integer Read / Write 0 = Off
1 = On
210
Event category (0738) 4261 Integer Read / Write 0 = Sensor
1 = Electronics
2 = Configuration
3 = Process
211
Diag. event sim. (0737) 4259 Integer Read / Write Off
Diagnostic event picklist (depends on
the category selected)
211
* Visibility depends on order options or device settings