Loading...
271
────────────────────────────────────────────────────
12.2 External Start/Stop
────────────────────────────────────────────────────
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Single stran
d
Multi-stran
d
1.0 mm diamete
r
(can be used 0.3 to 1.0 mm dia.
)
10 mm
10 mm
0.75 mm
2
(can be used 0.3 to 0.75 mm
2
Diameter per strand:
minimum 0.18 mm dia
.
Using the terminals
1. Push the tab with a flatblade screwdriver or similar.
2. While keeping the tab depressed, insert a stripped wire
into the connector opening.
3. Release the tab to lock the wire.
Recommended wire Single strand: 1.0 mm dia. (AWG #18)
Multi-strand: 0.75 mm
2
Usable limits Single strand: 0.3 to 1.0 mm dia. (AWG #26 to #18)
Multi-strand: 0.3 to 0.75 mm
2
(AWG #22 to #20)
Strand diameter: minimum 0.18 mm
Standard insulation 10 mm
stripping length