47
────────────────────────────────────────────────────
3.2 Basic Measurement and Setting Procedures
────────────────────────────────────────────────────
.2.4 Measuring and Recording an RMS Value (RMS Recorder
Function)
Example A signal going below 5 Vrms is captured.
(1) Input connection
Connect a signal generator to the 8835-01.
(2) Set the signal generator so that it outputs a sine wave of 50 Hz and 5 Vrms or
more.
(3) Settings on the STATUS 1 screen
Make the following settings with the CURSOR keys and function keys.
time/div: 5 s/DIV
frequency: 50 Hz
shot: 10 DIV
format: SINGLE
print mode: WAVE
additional recording: OFF
printer: OFF
auto save: OFF
(4) Settings on the STATUS 2 screen
Make the following settings with the CURSOR keys and function keys.
trigger mode: SINGLE
pre-trigger: 5 DIV
trigger source: AND
manual trigger: OFF
analog trigger: RMS level
trigger level: 5.00 V
trigger direction (slope): falling
Logic Trigger: OFF
timer trigger: OFF
external trigger: OFF