Chapter 4
|
Interface Configuration
Port Configuration
114
Cable diagnostics can only be performed on twisted-pair media.
This cable test is only accurate for Gigabit Ethernet cables 7 - 100 meters long.
The test takes approximately 5 seconds. The switch displays the results of the
test immediately upon completion, including common cable failures, as well as
the status and approximate length to a fault.
Potential conditions which may be listed by the diagnostics include those listed
below. Note that TDR testing can only show Test failed or OK.
Test failed
OK: Correctly terminated pair
Open: Open pair, no link partner
Short: Shorted pair
Impedance mismatch: Terminating impedance is not in the reference
range.
No cable
Not tested
Not Supported: This message is displayed for any Gigabit Ethernet ports
linked up at a speed lower than 1000 Mbps
Unknown Unknown error
Ports are linked down while running cable diagnostics.
Parameters
These parameters are displayed:
Port Switch port identifier.
Type Displays media type. (GE Gigabit Ethernet, Other SFP)
Link Status Shows if the port link is up or down.
Test Result The results include common cable failures, as well as the status
and approximate distance to a fault, or the approximate cable length if no fault
is found.
To ensure more accurate measurement of the length to a fault, first disable
power-saving mode on the link partner before running cable diagnostics.
For link-down ports, the reported distance to a fault is accurate to within +/- 2
meters. For link-up ports, the accuracy is +/- 10 meters.
Last Updated
Shows the last time this port was tested.
Test Initiates cable test.