834 Matrix ETERNITY NE System Manual
Thus the extension user sets Dynamic Lock, s/he manually selects the desired Toll Control Level for
his/her extension and restores the original Toll Control Level assigned to the extension.
Automatically: the extension user changes the Toll Control Level of the extension using the Dynamic
Lock Timer. The user sets the Timer to the desired number of minutes. On the expiry of this Timer, the
system restores the original Toll Control Level assigned to the extension.
For example, an organization has defined Toll Control Level 0 as Local Calls, and Level 3 as All Calls.
An extension user of this organization is assigned Level 0. When this extension user wants to make
international calls, the user sets the Dynamic Lock Timer and selects Toll Control Level 3. At the end of
the timer, Level 3 gets locked and Toll Control Level 0 is reapplied on the extension phone.
The changing of Toll Control level requires the extension user to dial the four-digit User Password. The
system will not accept the default User Password (1111). The extension user must first change the
default User Password.
The Dynamic Lock Timer can be set to a maximum of 99 minutes.
The Dynamic Lock Timer must be set to '00' when using Manual Dynamic Lock.
Dynamic Lock when set/canceled from the SA mode, will not depend on the assigned CoS.
How it works
The Pre-requisites
The Calls allowed for Lock Levels 0 (allowed for Day and Night/Break), Level 1, Level 2, and Level 3 are
configured in the Toll Control applied on the extension.
Dynamic Lock is allowed to the extension in its Class of Service.
The Process
For Dynamic Lock - Manual
The user of extension A sets the Dynamic Lock manually by entering the User Password and selecting the
desired Toll Control Level.
OR
The Operator sets Dynamic Lock manually for an extension by entering the extension number and
selecting the Toll Control Level.
For Dynamic Lock - Automatic
The user of extension A sets the Dynamic Lock by entering the User Password, setting the Dynamic Lock
Timer, and selecting the desired Toll Control Level.
OR
The Operator sets Dynamic Lock for an extension by entering the extension number, setting the Dynamic
Lock Timer and selecting the Toll Control Level.
Now, whenever a call is made from extension A, the system checks the Toll Control Level assigned to the
extension.
The system then checks the associated Lists of allowed and denied numbers.