Element Description
Network Variables0
Variable Name Description Data Type
Parameters the network adapters parameters
Network Status Contains the result of the last operation required
by writing inside the Adapter Parameters. It is
updated after each write operation.
l Empty string is meaning no errors
l Last error descriptions
string
read only
Subnet Mask Subnet Mask of the main Ethernet interface of
HMI
string
read only
PLCVariables
VariableName Description Data Type
Get
CopyCodesysProject
Action Status
Provides status of CopyCodesysProject action.
0 =Action not called
1 =Action in progress
2 =Action completed
3 =Action aborted (CHKfile missing)
4 = Action aborted (PRJ file missing)
5=Action aborted(SDBfile missing)
6=Action aborted(multiple CHK files found)
7=Action aborted(multiple PRJ files found)
8=Action aborted(multiple SDB files found)
9=Action aborted (inconsistent file names)
10 =Action aborted(unable to make directory)
11 =Action aborted (copy failed)
12 =Action aborted (Codesys module not
present)
int
read only
PLC Status Provides status of internal PLC.
0 =Run mode
int
HMWIN Studio |User Manual| v206 (2017-06-30) | EN| © 2014-2017 Panasonic Electric Works Europe AG