Remote control commands
R&S
®
SMA100B
518User Manual 1178.3834.02 ─ 09
Example:
SENS:SWE:HCOP:DEV FIL
Selects output device file.
:SENSe[:POWer]:SWEep:HCOPy:DEVice:LANGuage <Language>
Selects the bitmap graphic format for the screenshot of the power analysis trace.
In addition, ASCII file format *.csv is offered. If file format *.csv is selected, the
trace data is saved as an ASCII file with comma separated values. It is also possible to
directly retrieve the data using command :SENSe[:POWer]:SWEep:HCOPy:DATA?
on page 516
Parameters:
<Language> BMP | JPG | XPM | PNG | CSV
*RST: BMP
Example:
SENS:SWE:HCOP:DEV:LANG BMP
Selects output format *.bmp.
Manual operation: See "Format - Power Analysis" on page 281
:SENSe[:POWer]:SWEep:HCOPy:DEVice:LANGuage:CSV:DPOint <DPoint>
Defines which character is used as the decimal point of the values, either dot or
comma.
Parameters:
<DPoint> DOT | COMMa
*RST: DOT
Example:
SENS:SWE:HCOP:DEV:LANG CSV
Selects output format *.csv.
SENS:SWE:HCOP:DEV:LANG:CSV:DPO DOT
Selects character dot for being used as decimal point.
Manual operation: See "Decimal Point" on page 285
:SENSe[:POWer]:SWEep:HCOPy:DEVice:LANGuage:CSV:HEADer <Header>
Defines whether each row (or column depending on the orientation) should be prece-
ded by a header containing information about the trace (see also :SENSe[:POWer]:
SWEep:HCOPy:DATA? on page 516).
Parameters:
<Header> OFF | STANdard
*RST: OFF
Example:
SENS:SWE:HCOP:DEV:LANG CSV
Selects output format *.csv.
SENS:SWE:HCOP:DEV:LANG:CSV:HEAD STAN
Selects the standard header for the *.csv file.