Remote control commands
R&S
®
SMA100B
520User Manual 1178.3834.02 ─ 09
:SENSe[:POWer]:SWEep:HCOPy:FILE[:NAME] <Name>
Creates of selects a file for storing the hardcopy after the :SENSe[:POWer]:SWEep:
HCOPy[:EXECute] on page 524 command is sent. The directory is either defined
with the command MMEMory:CDIR or the path is specified together with the file name.
Access to the file via remote control is possible using the commands of the MMEM-
Subsystem. In contrast, command :SENSe[:POWer]:SWEep:HCOPy:DATA?
on page 516 transfers the hardcopy contents directly to the remote client where they
can be further processed.
Parameters:
<Name> string
Example:
SENS:SWE:HCOP:DEV:LANG BMP
Selects output format *,bmp.
SENS:SWE:HCOP:FILE:AUTO:STAT OFF
Switches off automatic naming.
SENS:SWE:HCOP:FILE 'var/trace/nrp_trace1'
creates the file nrp_trace1.bmp in the trace directory.
SENS:SWE:HCOP:EXEC
Triggers the generation of a hardcopy of the current trace. The
hardcopy is stored in the file nrp_trace1.bmp.
Manual operation: See "File name - Power Analysis" on page 280
:SENSe[:POWer]:SWEep:HCOPy:FILE[:NAME]:AUTO:DIRectory <Directory>
Defines the directory into which the hardcopy files are stored if auto naming is activa-
ted (SENS:SWE:HCOP:FILE:AUTO:STAT ON).
Parameters:
<Directory> string
Example:
SENS:SWE:HCOP:FILE:AUTO:DIR 'var/nrp'
Hardcopy file are stored in directory var/nrp if automatic nam-
ing is activated.
Manual operation: See "Path" on page 282
:SENSe[:POWer]:SWEep:HCOPy:FILE[:NAME]:AUTO:DIRectory:CLEar
Deletes all files with extensions bmp , img, png, xpm and csv in the directory set
for automatic naming.
Example:
SENS:SWE:HCOP:FILE:AUTO:DIR 'var/nrp'
Hardcopy filse are stored in directory var/nrp if automatic
naming is activated.
SENS:SWE:HCOP:FILEAUTO:DIR:CLE
Deletes all hardcopy file that are stored in the directory var/
nrp.
Usage: Event
Power sensor measurement subsystems