System programming in expert mod
e
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
7-21
Administration and maintenance
21 System settings
21 1 1 11 Music on hold, 0 = off/1 = on, always MOH/ 2 = on, with ringtone on
transfer
21 2 2 12 Telephone directory 0 = off/1 = on (internal telephone directory up
to SW 2.0.1+ only)
21 3 V.24 setup, 1 = 2400 baud/2 = 9600 baud
21 3 13 V.24 setup
21 3 13 1 MB baud rate, 1 = 2400 baud/2 = 9600 baud
21 3 13 2 Port allocation, 1 = port for CDRC/2 = port for call charges/ext./3 =
port for call charges/line/4 = port for customer data output/5 = port
for call info
21 4 External diversion, call connected, 0 = on answer/1 = immediately
21 4 14 External diversion
21 4 14 1 Connect call, 0 = on answer/1 = immediately
21 4 14 2 Call forwarding, 0 = disabled/1 = enabled
21 5 15 Caller list mode, 1 = external only/2 = external, internal
21 6 16 Automatic line reservation, 0 = off/1 = on
21 7 17 Tones and rings
21 7 17 1 Conference alerting tone, 0 = off/1 = on
21 7 17 2 Call pickup alerting ring, 0 = off/1 = on
21 8 18 Signal key (retrieval), 1 = press x 1/2 = press x 2
21 9 19 Classes of service
21 9 19 1 Night service, enter ext. 1–5
21 20 Automatic DTMF, 0=no/1= yes
21 21 Extend undialed line, 0=no/1= yes
Codes Function
ABC
A
= SW 2.0.1+;
B
= SW 2.0.2;
C
= SW 2.1
Table 7-4 Codes for expert mode