System programming in expert mod
A31003-K16-X001-3-7620, 07/99
Hicom 100 E Version 2.1, Service manual
7-25
Administration and maintenance
26 Sensors
26 1 1 1 Destination ext. number, select sensor 1–4 and enter extension,
group or external ext. number (with seizure code) (max. 23 charac-
ters)
26 2 2 2 Ext. number for announcement, select sensor 1–4 and enter exten-
sion or group ext. number (max. 5 characters)
26 3 3 3 Voice mail control data, select sensor 1–4 and enter control charac-
ter 0–9, *, # (max. 24 characters)
26 4 4 4 Call duration, select sensor 1–4 and enter 1–255
26 5 5 5 Call interval, select sensor 1–4 and enter 0–255
26 6 6 6 Number of calls, select sensor 1–4 and enter 1–255
26 7 7 7 Disable time, select sensor 1–4 and enter 0–255
26 8 8 8 Sensor name, select sensor 1–4, enter alphanumeric names (max.
16 characters)
Codes Function
ABC
A
= SW 2.0.1+;
B
= SW 2.0.2;
C
= SW 2.1
Table 7-4 Codes for expert mode