Commands listed in alphabetical order
Syntax
BUS:B<x>:ARIN
C429A:BITRate:CUSTom
<NR1>
BUS:B<x>:ARINC429A:BITRate :CUSTom?
Related Commands
BUS:B<x>:ARINC429A:BITRate
Arguments
<NR1> is the ARINC429 custom bit rate for the specified bus.
Examples
BUS:B1:ARINC429A:BITRATE:C USTOM 12500 sets the bit rate to 12,500.
BUS:B1:ARINC429A:BITRATE:C USTOM? might return
:BUS:B1:ARINC429A:BITRATE: CUSTOM 100000, indicating the bit
rate is set to 100,000.
BUS:B<x>:ARINC429A:DATAFORmat
This command sets or queries the format of the DATA field for the specified
ARINC429 bus. The bus is specified by x.
Conditions
Requires option SR-AERO.
Group
Bus
Syntax
BUS:B<x>:ARINC429A:DATAFOR mat {DATA|SDIDATA|SDIDATASSM}
BUS:B<x>:ARINC429A:DATAFOR mat?
Arguments
DATA specifiesaDATAfield width of 19 bits (covering bits 11 through 29 of
the 32 bit packet)
SDIDATA specifies a DATA field width of 21 bits (covering bits 9 through 29 of
the 32 bit packet)
SDIDATASSM specifiesaDATAfield width of 23 bits (covering bits 9 through
31 of the 32 bit packet)
Examples
BUS:B1:ARINC429A:DATAFORMA T SDIDATASSM sets Bus 1 ARINC429 DATA
field width to 23 bits.
BUS:B1:ARINC429A:DATAFORMA T? might return
:BUS:B1:ARINC429A:DATAFORM AT DATA, indicating a DATA field width
of 19 bits.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-115