Commands listed in alphabetical order
TRIGger:{A|B
}:BUS:B<x>:FLEXray:ERRTYPE
This command specifies the error type w hen triggering on the FlexRay
bus signal. The trigger condition needs to be set to ERROR (using
TRIGger:{A|
B}:BUS:B<x>:FLEXray:CONDition). The bus number is specified
by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:FL EXray:ERRTYPE
{CRCHeader|CRCTrailer|SYN CFrame|STARTupnosync|NULLFRStatic|
NULLFRDynamic}
TRIGger:{A|B}:BUS:B<x>:FL EXray:ERRTYPE?
Arguments
CRCHeader sets the error type to CRCHeader.
CRCTrailer sets the error type to CRCTrailer.
SYNCFrame sets the error type to SYNCFrame.
STARTupnosync sets the error type to STA RTupnosync.
NULLFRStatic sets the error type to NULLFRStatic.
NULLFRDynamic sets the error type to NULLFRDynamic.
Examples
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE SYNCFRAME sets the trigger type
is SYNCFRAME.
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE? might return
TRIGGER:A:BUS:B1:FLEXRAY: ERRTYPE CRCHEADER indicating the
FlexRay trigger type is CRCHeader.
TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEID:HIVALue
This command specifies the high value when triggering on the FlexRay bus
frame ID field. (Use TRIGger:{A|B}:BUS:B<x>:FLEXray:FRAMEID:VALue
to set the low value.) The trigger condition needs to be set to IDentifier (using
TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition). The bus number is specified
by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
2-800 MSO54, MSO56, MSO58, MSO58LP Programmer