EasyManuals Logo
Home>Tektronix>Test Equipment>MSO56

Tektronix MSO56 User Manual

Tektronix MSO56
1026 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #499 background imageLoading...
Page #499 background image
Commands listed in alphabetical order
Examples
MEASUrement:M
EAS1:RESUlts:CURRentacq:MAXi mum?
might return
:MEASUREMENT:MEAS1:RESULTS :CURRENTACQ:MAXIMUM 2.280 indicating
the current measurement maximum value is 2.28 V.
MEASUrement
:MEAS<x>:RESUlts:CURRentacq:MEAN? (Query Only)
This query-only command returns the mean value for the measurement for the
current acquisition. The measurement number is specied by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:RESUlt s:CURRentacq:MEAN?
Returns
The mean value accumulated for the specied measurement since the last
statistical reset.
Examples
MEASUrement:MEAS1:RESUlts: CURRentacq:MEAN? might return
:MEASUREMENT:MEAS1:RESULTS :CURRENTACQ:MEAN 2.30 indicating the
mean of the measurement in the current acquisition is 2.3 V.
MEASUrement:MEAS<x>:RESUlts:CURRentacq:MINimum? (Query Only)
This query-only command returns the minimum value found for the specied
measurement since the last statistical reset. The measurement number is specied
by x.
Group
Measurement
Syntax
MEASUrement:MEAS<x>:RESUlt s:CURRentacq:MINimum?
Returns
The minimum value found for the specied measurement since the last statistical
reset.
Examples
MEASUrement:MEAS1:RESUlts: CURRentacq:MINimum? might return
:MEASUREMENT:MEAS1:RESULTS :CURRENTACQ:MINIMUM 2.260 indicating
the minimum value of the measurement in the current acquisition is 2.26 V.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-483

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO56 and is the answer not in the manual?

Tektronix MSO56 Specifications

General IconGeneral
BrandTektronix
ModelMSO56
CategoryTest Equipment
LanguageEnglish

Related product manuals