Commands listed in alphabetical order
Examples
SEARCH:SEARCH
1:TRIGger:A:BUS:FLEXray:FRAM EID:QUALifier
UNEQUAL
sets the qualifier to unequal.
SEARCH:SEARCH1:TRIGger:A: BUS:FLEXray:FRAMEID:QUALifier?might
return
:SEARCH:SEARCH1:TRIGGER:A: BUS:FLEXRAY:FRAMEID:QUALIFIER
EQUAL
indicating the qualifier is set to equal.
SEARCH:SEARCH<x>:TRIGger:A:BUS:FLEXray:FRAMEID:VALue
This command sets the low value when searching on a FlexRay bus id field. The
search condition must b e set to IDentifier. The search number is specified by <x>.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:FLEXray:FRAMEID:VALue
<QString>
SEARCH:SEARCH<x>:TRIGger: A:BUS:FLEXray:FRAMEID:VALue?
Arguments
<QString> is the frame id value.
Examples
SEARCH:SEARCH1:TRIGger:A: BUS:FLEXray:FRAMEID:VALue
"XXXXXXX1010"
sets the value to XXXXXXX1010.
SEARCH:SEARCH1:TRIGger:A: BUS:FLEXray:FRAMEID:VALue? might
return
:SEARCH:SEARCH1:TRIGGER:A: BUS:FLEXRAY:FRAMEID:VALUE
"XXXXXXXXXXX"
indicating the value is XXXXXXXXXXX.
SEARCH:SEARCH<x>:TRIGger:A:BUS:FLEXray:FRAMEType
This command sets or queries the FlexRay bus search frame type. The search
number is specified by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Search and Mark
Syntax
SEARCH:SEARCH<x>:TRIGger: A:BUS:FLEXray:FRAMEType
{NORMal|PAYload|NULL|SYNC |STARTup}
SEARCH:SEARCH<x>:TRIGger: A:BUS:FLEXray:FRAMEType?
Arguments
Arguments are the available frame types.
2-670 MSO54, MSO56, MSO58, MSO58LP Programmer