Commands listed in alphabetical order
Conditions
Requires the SR
-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:STATus:BIT:SUBSF
{ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:STATus:BIT:SUBSF?
Arguments
ONE lters status words to only match those where the SUBSF bit h as a value of 1.
ZERo lters status words to only match those where the SUBSF bit has a value
of 0.
NOCARE disables ltering of status words on the SUBSF bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B: STATUS:BIT:SUBSF ONE species ltering
status words for those where the SUBSF bit has a value of 1.
TRIGGER:A:BUS:B1:MIL1553B: STATUS:BIT:SUBSF? might return
NOCARE, indicating that status words are not being ltered based on the SUBSF
bit value.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:STATus:BIT:TF
This command sets or queries the value of the terminal ag bit (TF bit, bit 19)
in a status word for a MIL-STD-1553 bus to triggering on. The bus number is
specied by x. The trigger condition must be set to STATus.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:STATus:BIT:TF
{ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:STATus:BIT:TF?
Arguments
ONE lters status words to only match those where the TF bit has a value of 1 .
ZERo lters status words to only match those where the TF bit has a value of 0.
NOCARE disables ltering of status words on the TF bit.