Commands listed in alphabetical order
MEASUREMENT:C
H2:REFLEVELS:BASETOP?
might return
:MEASUREMENT:CH2:REFLEVELS :BASETOP AUTO indicating the
reference levels a re chosen automatically.
MEASUrement
:CH<x>:REFLevels:METHod
This command sets or queries the method used to calculate reference levels for the
measurement. The channel number is specified by x.
Group
Measurement
Syntax
MEASUrement:CH<x>:REFLevel s:METHod {PERCent|ABSolut e}
MEASUrement:CH<x>:REFLevel s:METHod?
Arguments
PERCent specifi es percent reference level units.
ABSolute specifi es absolute reference level units.
Examples
MEASUREMENT:CH2:REFLEVELS: METHOD PERCENT sets reference levels to be
calculated in percent.
MEASUREMENT:CH2:REFLEVELS: METHOD? might return
:MEASUREMENT:CH2:REFLEVELS :METHOD PERCENT indicating the
reference levels are calculated in percent.
MEASUrement:CH<x>:REFLevels:PERCent:FALLHigh
This command sets or queries the percentage (where 100% is equal to TOP and
0% is equal to BASE) used to calculate the high reference level of the falling
edge when the source ref level method is set to percent. The channel number
is specified by x.
Group
Measurement
Syntax
MEASUrement:CH<x>:REFLevel s:PERCent:FALLHigh <NR3>
MEASUrement:CH<x>:REFLevel s:PERCent:FALLHigh?
Arguments
<NR3> isthepercentage(where100%isequal to TOP) used to calculate the hig
h
reference level when the measurement's Ref l evel method is set to Percent.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-387