Commands listed in alphabetical order
Examples
POWer:POWer1:
SWITCHINGRIPPLE:SFREQuency 60000
sets the frequency
present for line ripple measurement as 60000 Hz.
POWer:POWer<x>:TYPe
This command sets or quer ies the measurement type for the specied power
measurement badge. The power m easurement badge is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWer:POWer<x>:TYPe <Measurement Type>
POWer:POWer<x>:TYPe?
Arguments
<Measurement Type> = SOA | SWITCHINGLOss | CYCLEAmp |
CYCLEMAx | CYCLEMIn | CYCLEPKpk | SWITCHINGRIpple | LINERIpple
| NDUTYCycle | NPULSEWidth | PDUTYCycle | PPULSEWidth | DIDT |
DVDT | FREQuency | HARMonics | CYCLETop | CYCLEBase | PERIod |
POWERQUALity
Examples
POWer:POWer1:TYPe POWERQUALITY adds Power1 measurement badge and
selects the Power Quality measurement.
POWERTABle:ADDNew (No Query F orm)
This command adds the power harmonics table. The power measurement badge
is specied by x.
Conditions
Requires option 5-PWR, SUP5-PWR, or 5-PS2.
Group
Power
Syntax
POWERTABle:ADDNew TABLE<x>
Arguments
<x> must be greater than or equal to one.
Examples
POWTABle:ADDNew "TABLE1" adds power harmonics table.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-595

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix MSO56 and is the answer not in the manual?

Tektronix MSO56 Specifications

General IconGeneral
BrandTektronix
ModelMSO56
CategoryTest Equipment
LanguageEnglish

Related product manuals