Commands listed in alphabetical order
Examples
MEASUREMENT:F
ILTERS:HIGHPASS:SPEC NONE
specifies no high pass filter.
MEASUREMENT:FILTERS:HIGHP ASS:SPEC? might return
:MEASUREMENT
:FILTERS:HIGHPASS:SPEC SECOND
indicating a
second order high pass filter.
MEASUrement:FILTers:LOWPass:FREQ
This command sets or queries the global low pass filter cutoff frequency for the
measurement.
Group
Measurement
Syntax
MEASUrement:FILTers:LOWPa ss:FREQ <NR3>
MEASUrement:FILTers:LOWPa ss:FREQ?
Arguments
<NR3> is the current low pass filter frequency.
Examples
MEASUREMENT:FILTERS:LOWPA SS:FREQ 20.0e6 sets the low pass frequency
to 20 MHz.
MEASUREMENT:FILTERS:LOWPA SS:FREQ? might return
:MEASUREMENT:FILTERS:LOWP ASS:FREQ 10.0000E+6 indicating
the low pass frequency is 10.0 MHz.
MEASUrement:FILTers:LOWPass:SPEC
This command sets or q u
eries the global low pass filter order for the measurement.
Group
Measurement
Syntax
MEASUrement:FILTers:LOWPa ss:SPEC {NONE|FIRST|SECON D|THIRD}
MEASUrement:FILTers:LOWPa ss:SPEC?
Arguments
NONE specifies no low pass filter.
FIRST specifies a first order low pass filter.
SECOND specifies a second order low pass filter.
THIRD specifies a third order low pass filter.
2-404 MSO54, MSO56, MSO58, MSO58LP Programmer