Commands listed in alphabetical order
TRIGger:{A|B
}:BUS:B<x>:MIL1553B:DATa:PARity
This command sets or queries the value of the command word parity bit for a
MIL-STD-1553 bus to triggering on. The bus number is s pecified by x. The
trigger cond
ition must be set to DATA.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:DATa:PARity {ONE|ZERo|NOCARE}
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:DATa:PARity?
Arguments
ONE filters data words to only match those where the parity bit has a value of 1.
ZERo filters data words to only match those where the p arity bit has a value of 0.
NOCARE disables filtering of data words on the parity bit.
Examples
TRIGGER:A:BUS:B1:MIL1553B: DATA:PARITY ONE specifies fi ltering data
words for those where the parity bit has the value 1.
TRIGGER:A:BUS:B1:MIL1553B: DATA:PARITY? might return NOCARE,
indicating that data words are not being filtered based on the parity bit value.
TRIGger:{A|B}:BUS:B<x>:MIL1553B:DATa:VALue
This command sets or queries the value when triggering on data words for a
MIL-STD-1553 bus. The bus number is specified by x. The trigger condition
must be set to DATA.
Conditions
Requires the SR-AERO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:DATa:VALue <QString>
TRIGger:{A|B}:BUS:B<x>:MIL 1553B:DATa:VALue?
Arguments
<QString> is the data value.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-819