Page #44 background image
Command groups
Display control command group
Display commands can be found in this section as well as the sections of related
components. These commands control general oscilloscope settings, such a s the
intensity of the graticule, stacked or overlay display mode, and the fastacq color
palette. Display commands also control how and where w aveforms are shown,
their posit
ion on screen, and zoom settings applied to the view. For example,
display commands c an turn on or off the display of channels or set the selected
source.
Some actions can create a new view which can have its own settings. For example,
adding a histogram w ill create a new view where the Histogram plot is displayed.
Each view acts as a separate window within the oscilloscope application and can
be rearranged or annotated as desired.
A WaveView is the primary view used for viewing inputs and time-domain
signals. Buses, non-FFT maths, refs, analog and digital channels, and time-trends
are displayed in the WaveView.
A PlotView is used for viewing m easurement results and other plotted data.
Histograms, eye diagrams, XY/XYZ plots, FFTs, and other plots are shown in
individual PlotViews.
Each of these views can h ave separate settings, zoom, cursors, and annotations.
Display commands which are view specichaveaviewparameterin
the programmable interface, such as DISPLAY:WAVEView<x>: ... or
DISPLAY:PLOTView<x>: ... Selected source can also be specied on a per-view
basis. The overall selected source is determined by the selected vie w and the
selected source w ithin that view.
PlotViews and WaveViews have some differences in command syntax due to
differences in view functionality. For example, WaveViews and PlotViews have
a different zoom model. The commands for specifying the zoom reects these
differences, and different command syntax is available depending on the view.
Table 2-25: Display control commands
Command
Description
DISplay?
Returns current display settings.
DISplay:COLors Sets or queries the color mode for the graticule and waveform display.
DISplay:GLObal:B<x>:STATE Sets or queries the display mode (on or off) of the specied bus.
DISplay:GLObal:CH<x>:STATE Sets or queries the display mode (on or o ff) of the specied channel (both analog
and digital).
DISplay:GLObal:MATH<x>:STATE Sets or queries the display mode (on or off) of the specied math.
DISplay:GLObal:PLOT<x>:STATE Sets or queries the display mode (on or off) of the specied time trend plot.
DISplay:GLObal:REF<x>:STATE Sets or queries the display m ode (on or off) of the specied reference.
DISplay:INTENSITy? Returns the waveform and graticule saturation levels.
DISplay:INTENSITy:BACKLight Sets or queries the waveform backlight intensity settings.
2-28 MSO54, MSO56, MSO58, MSO58LP Programmer