Commands listed in alphabetical order
Conditions
Requires the SR
-EMBD Triggering a nd Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:I2C :ADDRess:VALue <QString>
TRIGger:{A|B}:BUS:B<x>:I2C :ADDRess:VALue?
Arguments
<QString> is up to 7 or 10-bits depending on the address mode that specifies the
address. The only allowed characters in the
QString are 0, 1, and X.
Examples
TRIGGER:A:BUS:B1:I2C:ADDRE SS:VALUE "1011" sets the I
2
C address value
to XXX1011.
TRIGGER:A:BUS:B1:I2C:ADDRE SS:VALUE? might return
:TRIGGER:A:BUS:B1:I2C:ADDR ESS:VALUE "XXXXXXX" indicating
the address value is set to XXXXXXX.
TRIGger:{A|B}:BUS:B<x>:I2C:CONDition
This command specifies the trigger condition for an I
2
C trigger. The bus number
is specified by <x>.
Conditions
Requires the SR-EMBD Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:I2C :CONDition
{STARt|STOP|REPEATstart|AC KMISS|ADDRess|DATa|ADDRANDDATA}
TRIGger:{A|B}:BUS:B<x>:I2C :CONDition?
Arguments
STARt specifies a search based on start condition.
STOP specifies a search based on stop condition.
REPEATstart specifies a search b ased on repeat of start condition.
ACKMISS specifies a search based on missing acknowledgement condition.
ADDRess specifies a search based on addres s.
DATa specifies a search based on data.
ADDRANDDATA specifies a search based on address and data.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-807