Commands listed in alphabetical order
Group
Trigger
Syntax
TRIGger:{A|B}:SETHOLDLogic val:{CH<x>|CH<x>_D<x>}
{INCLude|DONTInclude}
TRIGger:{A|B}:SETHOLDLogic val:{CH<x>|CH<x>_D<x>}?
Arguments
INCLude specifies including the specified channel in the Setup & Hold trigger
input configuration.
DONTInclude specifies not including the specifiedchannelintheSetup&Hold
trigger input configuration.
Examples
TRIGger:A:SETHOLDLogicval: CH1 INCLUDE specifies including the
specified channel in the Setup & Hold trigger input configuration.
TRIGger:A:SETHOLDLogicval: CH1? might include
:TRIGGER:A:SETHOLDLOGICVAL :CH1 DONTINCLUDE indicating not
to include the channel in the configuration.
TRIGger:A:SETHOLDLogicval: CH1_D0 include specifies including the
specified channel in the setup and hold trigger input configuration.
TRIGger:A:SETHOLDLogicval: CH1_D0? might return
:TRIGGER:A:SETHOLDLOGICVAL :CH1_D0 DONTINCLUDE indicating
the channel will not be included in the configuration.
TRIGger:{A|B}:TIMEOut:LOGICQUALification
This command specifi es whether or not to use logic qualification for a timeout
trigger.
Group
Trigger
Syntax
TRIGger:{A|B}:TIMEOut:LOGI CQUALification {ON|OFF}
TRIGger:{A|B}:TIMEOut:LOGI CQUALification?
Arguments
ON specifies that the timeout trigger type uses logic qualification.
OFF specifies that the timeout trigger type does not use logic qualification.
Examples
TRIGger:A:TIMEOut:LOGICQUA Lification ON specifies using logic
qualification.