Commands listed in alphabetical order
Examples
TRIGGER:A:BUS
:B1:FLEXRAY:HEADER:FRAMEID "11001100101"
sets the
frame ID portion of the binary header string to 11001100101.
TRIGGER:A:BU
S:B1:FLEXRAY:HEADER:FRAMEI D?
might return
TRIGGER:A:BUS:B1:FLEXRAY:H EADER:FRAMEID "XXXXXXXXXXX"
indicating the frame ID portion of the binary header string is "don't care".
TRIGger:{A
|B}:BUS:B<x>:FLEXray:HEADER:INDBits
This command specifies the indicator bits portion of the binary header string
when triggering on the FlexRay bus header. The trigger condition needs to be set
to HEADer
(using TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition). The bus
number is specified by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
Syntax
TRIGger:{A|B}:BUS:B<x>:FLE Xray:HEADER:INDBits <QStr ing>
TRIGger:{A|B}:BUS:B<x>:FLE Xray:HEADER:INDBits?
Arguments
<QString> is a quoted string that is the indicator bits portion of the binary
header string.
Examples
TRIGGER:A:BUS:B1:FLEXRAY:H EADER:INDBITS "11001" sets the indicator
bits portion of the header string to 11001.
TRIGGER:A:BUS:B1:FLEXRAY:H EADER:INDBITS? might return
TRIGGER:A:BUS:B1:FLEXRAY:H EADER:INDBITS "XXXXX" indicating that
the indicator bits portion of the header string are "don't cares".
TRIGger:{A|B}:BUS:B<x>:FLEXray:HEADER:PAYLength
This command specifies the p ayload length portion of the binary header string
when triggering on the FlexRay bus header. The trigg
er condition needs to be set
to HEADer (using TRIGger:{A|B}:BUS:B<x>:FLEXray:CONDition).The bus
number is specified by <x>.
Conditions
Requires the SR-AUTO Triggering and Analysis application.
Group
Trigger
MSO54, MSO56, MSO58, MSO58LP Programmer 2-805