Commands listed in alphabetical order
Examples
BUS:B1:FLEXRA
Y:CHANNEL B
sets the FlexRay channel to B.
BUS:B1:FLEXRAY:CHANNEL? might return :BUS:B1:FLEX RAY:CHANNEL A,
indicating th
e channel is set to A.
BUS:B<x>:FLEXray:LOWTHRESHold
This command sets or queries the FlexRay data source low threshold for the
specied bus. The bus is specied by x.
Conditions
Requires option SR-AUTO.
Group
Bus
Syntax
BUS:B<x>:FLEXray:LOWTHRESH old <NR3>
BUS:B<x>:FLEXray:LOWTHRESH old?
Arguments
<NR3> is the FlexRay data source low threshold for the specied bus.
Examples
BUS:B1:FLEXray:LOWTHRESHol d 50.0e-3 sets the threshold to 50 mV.
BUS:B1:FLEXray:LOWTHRESHol d? might
:BUS:B1:FLEXray:LOWTHRESHO LD 0.0E+0 indicating the threshold is
set to 0.0 V.
BUS:B<x>:FLEXray:SIGnal
This command sets or queries the FlexRay signal type for the specied bus. The
bus number is specied by x.
Conditions
Requires option SR-AUTO.
Group
Bus
Syntax
BUS:B<x>:FLEXray:SIGnal {BDIFFBP|BM|TX RX}
BUS:B<x>:FLEXray:SIGnal?
Arguments
BDIFFBP sets the FlexRay signal type to BDIFFBP.
BM s
ets the FlexRay signal type to BM.
MSO54, MSO56, MSO58, MSO58LP Programmer 2-141