Command groups
Table 2-25: Display control commands (cont.)
Command
Description
DISplay:WAVEView<x>:CH<x>_DALL:
VERTical:POSition
Sets or queries the vertical position of the specified digital channel in the specified
waveview in divisions.
DISplay:WAVEView<x>:CH<x>_D<x>:STATE Sets or queries the display state of the specified digital channel in the specified
waveview.
DISplay:WAVEView<x>:FILTer Sets or queries the type of interpolation filter for the display.
DISplay:WAVEView<x>:GRAticule Selects or queries the type of graticule that is displayed.
DISplay:WAVEView<x>:INTENSITy:
GRATicule
Sets or queries the graticule saturation l evel.
DISplay:WAVEView<x>:INTENSITy:
WAVEform
Sets or queries the waveform saturation level.
DISplay:WAVEView<x>:MATH:MATH<x>:
AUTOScale
Sets or queries whether the specified math gets auto-scaled when the math
equation changes within the specified waveview.
DISplay:WAVEView<x>:MATH:MATH<x>:
STATE
Sets or queries the state of the specified math waveform in the specified waveview.
DISplay:WAVEView<x>:MATH:MATH<x>:
VERTical:POSition
Sets or queries the vertical position in divisions of the specified math wave form .
DISplay:WAVEView<x>:MATH:MATH<x>:
VERTical:SCAle
Sets or queries the vertical scale of the specified math waveform.
DISplay:WAVEView<x>:PLOT:PLOT<x>:
AUTOScale
Sets or queries whether the specified math gets auto-scaled when the math
equation changes within the specified waveview.
DISplay:WAVEView<x>:PLOT:PLOT<x>:
STATE
Sets or queries the state of the specified trend waveform in the specified waveview.
DISplay:WAVEView<x>:PLOT:PLOT<x>:
VERTical:POSition
Sets or queries the vertical position of the specified time trend in the specified
waveview in divisions.
DISplay:WAVEView<x>:PLOT:PLOT<x>:
VERTical:SCAle
Sets or queries the vertical scale of the specified time trend in volts per division in
the specified waveview.
DISplay:WAVEView<y>:REF<x>_DALL:
FRAMe
Sets or returns the selected frame of the specified digital ref.
DISplay:WAVEView<y>:REF:REF<x>:
FRAMe
sets or returns the selected frame of the specified analog ref.
DISplay:WAVEView<x>:REF:REF<x>:STATE Sets or queries the state of the specified reference waveform in the specified
waveview.
DISplay:WAVEView<x>:REF:REF<x>:
VERTical:POSition
Sets or queries the vertical position in divisions of the specified reference waveform.
DISplay:WAVEView<x>:REF:REF<x>:
VERTical:SCAle
Sets or queries the vertical scale of the specified reference waveform.
DISplay:WAVEView<x>:STYle Sets or queries the waveforms are displayed for analysis mode.
DISplay:WAVEView<x>:VIEWStyle Sets or queries the waveform layout style used by the display.
DISPLAY:PLOTVIEW<x>:XAXIS:SCALE Sets or queries the horizontal scale setting for applicable plots, either Linear or Log.
DISPLAY:PLOTVIEW<x>:YAXIS:SCALE Sets or queries the vertical scale setting for applicable plots, either Linear or Log.
2-30 MSO54, MSO56, MSO58, MSO58LP Programmer

Table of Contents