Maintenance
2751−2/A1
RT-flex50-D
Wärtsilä Switzerland Ltd
9/ 9
4. Blocking of exhaust valve
The engine operation must be interrupted temporarily for blocking an exhaust
valve.
In case of an emergency, i.e. with water leakages into the combustion chamber
damper 33 can be removed and the exhaust valve blocked in open position by
means of pressure element 94259a. The latter must also be fitted if an exhaust
valve is jammed in the open position (see 0520−1 in the Operating Manual).
J
37 mm
94259a
42
WCH00681
DRAWN FOR
RT−flex48T−D
2011-12
E
xhaust Valve: Dismantling and Assembling