EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 700

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn419 2 Third Stage
Notch Filter
Depth
0 to 1,000 0.001 0 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn41A 2 Fourth Stage
Notch Filter
Frequency
50 to
5,000
1 Hz 5000 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn41B 2 Fourth Stage
Notch Filter Q
Value
50 to
1,000
0.01 70 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn41C 2 Fourth Stage
Notch Filter
Depth
0 to 1,000 0.001 0 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn41D 2 Fifth Stage
Notch Filter
Frequency
50 to
5,000
1 Hz 5000 All Immedi-
ately
Tuning
Ä
Chap.
9.14.2
‘Tuning
the Servo
Gains’
page 406
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 700

Table of Contents