n.X
/V-CMP (Speed Coincidence Detection Output) Signal
Allocation
Reference
0 to
6
The allocations are the same as the /COIN (Posi-
tioning Completion) signal allocations.
Ä
Chap. 7.2.8
‘/V-CMP
(Speed Coinci-
dence Detec-
tion) Signal’
page 202
n.X
/TGON (Rotation Detection Output) Signal Allocation Reference
0 to
6
The allocations are the same as the /COIN (Posi-
tioning Completion) signal allocations.
Ä
Chap. 7.2.6 ‘/
TGON (Rota-
tion Detection)
Signal’
page 200
n.X
/S-RDY (Servo Ready) Signal Allocation Reference
0 to
6
The allocations are the same as the /COIN (Posi-
tioning Completion) signal allocations.
Ä
Chap. 7.2.6 ‘/
TGON (Rota-
tion Detection)
Signal’
page 200
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn50F 2 Output Signal
Selections 2
0000h to
6666h
– 0100h All After
restart
Setup –
n.X
/CLT (Torque Limit Detection Output) Signal Alloca-
tion
Reference
0 Disabled (the above signal output is not used).
Ä
Chap. 7.8.4
‘/CLT (Torque
Limit Detection)
Signal’
page 227
1 Output the signal from the CN1-1 or CN1-2 output
terminal.
2 Output the signal from the CN1-23 or CN1-24
output terminal.
3 Output the signal from the CN1-25 or CN1-26
output terminal.
4 to
6
Reserved setting (Do not use.)
n.X
/VLT (Speed Limit Detection) Signal Allocation Reference
0 to
6
The allocations are the same as the /CLT (Torque
Limit Detection Output) signal allocations.
Ä
‘/VLT (Speed
Limit Detection)
Signal’
page 207
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 712