EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 714

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn511 2 Input Signal
Selections 5
0000h to
FFFFh
8543h All After
restart
Setup
Ä
Chap.
7.2.2
‘Input
Signal
Alloca-
tions’
page 196
n.X
/DEC (Home Switch Input) Signal Allocation
0 Active when CN1-13 input signal is ON (closed).
1 Active when CN1-7 input signal is ON (closed).
2 Active when CN1-8 input signal is ON (closed).
3 Active when CN1-9 input signal is ON (closed).
4 Active when CN1-10 input signal is ON (closed).
5 Active when CN1-11 input signal is ON (closed).
6 Active when CN1-12 input signal is ON (closed).
7 The signal is always active.
8 The signal is always inactive.
9 Active when CN1-13 input signal is OFF (open).
A Active when CN1-7 input signal is OFF (open).
B Active when CN1-8 input signal is OFF (open).
C Active when CN1-9 input signal is OFF (open).
D Active when CN1-10 input signal is OFF (open).
E Active when CN1-11 input signal is OFF (open).
F Active when CN1-12 input signal is OFF (open).
n.X
/EXT1 (Probe 1 Latch Input) Signal Allocation
0 The signal is always inactive.
1 The signal is always inactive.
2 The signal is always inactive.
3 The signal is always inactive.
4 Active when CN1-10 input signal is ON (closed).
5 Active when CN1-11 input signal is ON (closed).
6 Active when CN1-12 input signal is ON (closed).
7 The signal is always inactive.
8 The signal is always inactive.
9 The signal is always inactive.
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters