EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 718

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn51B 4 Motor-Load
Position Devi-
ation Over-
flow Detec-
tion Level
0 to
1,073,741
,823
1 refer-
ence unit
1000 Rotary Immedi-
ately
Setup
Ä
Chap.
11.4.8
‘Alarm
Detection
Settings’
page 461
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn51E 2 Position Devi-
ation Over-
flow Warning
Level
10 to 100 1% 100 All Immedi-
ately
Setup
Ä
Chap.
16.5.2.3
‘List of the
SERVO-
PACK
Warnings’
page 638
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn520 4 Position Devi-
ation Over-
flow Alarm
Level
1 to
1,073,741
,823
1 refer-
ence unit
5242880 All Immedi-
ately
Setup
Ä
Chap.
9.4.4 ‘Set-
ting the
Position
Deviation
Overflow
Alarm
Level’
page 300,
Ä
Chap.
16.4.2
‘List of
Alarms’
page 586
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn522 4 Positioning
Completed
Width
0 to
1,073,741
,824
1 refer-
ence unit
7 All Immedi-
ately
Setup
Ä
Chap.
7.2.9 ‘/
COIN
(Posi-
tioning
Comple-
tion)
Signal’
page 203
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 718

Table of Contents

Related product manuals