EasyManua.ls Logo

YASKAWA Sigma-7 SGD7S Series - Page 719

YASKAWA Sigma-7 SGD7S Series
768 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn524 4 Near Signal
Width
1 to
1,073,741
,824
1 refer-
ence unit
10737418
24
All Immedi-
ately
Setup
Ä
Chap.
7.2.10 ‘/
NEAR
(Near)
Signal’
page 205
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn526 4 Position Devi-
ation Over-
flow Alarm
Level at
Servo ON
1 to
1,073,741
,823
1 refer-
ence unit
5242880 All Immedi-
ately
Setup
Ä
Chap.
9.4.6 ‘Set-
ting the
Position
Deviation
Overflow
Alarm
Level at
Servo ON’
page 302
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn528 2 Position Devi-
ation Over-
flow Warning
Level at
Servo ON
10 to 100 1% 100 All Immedi-
ately
Setup
Ä
Chap.
9.4.6 ‘Set-
ting the
Position
Deviation
Overflow
Alarm
Level at
Servo ON’
page 302
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn529 2 Speed Limit
Level at
Servo ON
0 to
10,000
1 min
-1
10000 Rotary Immedi-
ately
Setup
Ä
Chap.
9.4.6 ‘Set-
ting the
Position
Deviation
Overflow
Alarm
Level at
Servo ON’
page 302
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 719

Table of Contents