Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn61B
*9
2 Overheat
Alarm Level
0 to 500 0.01 V 250 All Immedi-
ately
Setup
Ä
Chap.
7.15.3
‘Overheat
Protection
Selec-
tions’
page 261
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn61C
*9
2 Overheat
Warning
Level
0 to 100 1% 100 All Immedi-
ately
Setup
Ä
Chap.
7.15.3
‘Overheat
Protection
Selec-
tions’
page 261
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn61D
*9
2 Overheat
Alarm Filter
Time
0 to
65,535
1 s 0 All Immedi-
ately
Setup
Ä
Chap.
7.15.3
‘Overheat
Protection
Selec-
tions’
page 261
Param-
eter No.
Size Name Setting
Range
Setting
Unit
Default
Setting
Appli-
cable
Motors
When
Enabled
Classifi-
cation
Refer-
ence
Pn621 to
Pn628
*4
– Safety
Module-
Related
Parameters
– – – All – – –
*1. Set a percentage of the motor rated torque.
*2. Normally set this parameter to 0. If you use an External Regenerative Resistor, set the
capacity (W) of the External Regenerative Resistor.
*3. The upper limit is the maximum output capacity (W) of the SERVOPACK.
*4. These parameters are for SERVOPACKs with a Safety Module. Refer to the following
manual for details.
& Σ-V-Series/Σ-V-Series for Large-Capacity Models/Σ-7-Series User’s Manual Safety
Module (Manual No.: SIEP C720829 06)
Sigma-7 Series SERVOPACKs
Parameter and Object Lists
List of Parameters > List of Parameters
| | PROFINET Communications - SIEP YEUOC7P 02A Revision 0 | en | 728