Data Capture
40
Low beep Default Green LED
based upon hand-held
or hands-free mode
Snapshot mode completed.
High/low beeps Default Green LED
based upon hand-held
or hands-free mode
Snapshot mode timed-out.
Parameter Programming
Long low/long high beeps Red Input error; incorrect barcode or Cancel scanned, wrong
entry, incorrect barcode programming sequence; remain
in program mode.
High/low beeps Green Number expected. Enter value using numeric barcodes.
High/low/high/low beeps Green Successful program exit with change in the parameter
setting.
ADF Programming
Low/high/low beeps None ADF transmit error.
High/low beeps Green Number expected. Enter another digit. Add leading zeros
to the front if necessary.
Low/low beeps Green Alphanumeric expected. Enter another alphanumeric
character or scan the End of Message barcode.
High/high beeps Green blinking ADF criteria or action is expected. Enter another criteria
or action or scan the Save Rule barcode.
High/low/low beeps Green All criteria or actions cleared for current rule, continue
entering rule.
High/low/high/low beeps Green
(turns off after blinking)
Rule saved. Rule entry mode exited.
Long low/long high beeps Red Rule error. Entry error, wrong barcode scanned, or
criteria/action list is too long for a rule. Re-enter criteria or
action.
Low beep Green Deleted last saved rule. The current rule is left intact.
Low/high/high beeps Green All rules deleted.
Long low/long high/long
low/long high beeps
Red Out of rule memory. Erase some existing rules, then try
to save rule again.
Long low/long high/long
low beeps
Green
(turns off after blinking)
Cancel rule entry. Rule entry mode exited because of an
error or the user asked to exit rule entry.
Host Specific
USB only
Four high beeps None
Scanner has not completed initialization. Wait several
seconds and scan again.
RS-232 only
Low/low/low/extra low
beeps
Red RS-232 receive error (parity error).
High beep None A <BEL> character is received when Beep on <BEL> is
enabled (Point-to-Point mode only).
Table 3 Scanner Speaker and LED Indications (Continued)
Speaker Sequence LED Indication

Table of Contents

Other manuals for Zebra DS9908

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS9908 and is the answer not in the manual?

Zebra DS9908 Specifications

General IconGeneral
SealingIP52
Scan TechnologyArray Imager
Scan RateUp to 240 in./610 cm per second
Humidity5% to 95% RH, non-condensing
Decode Capability1D, 2D
ConnectivityUSB, RS-232, Keyboard Wedge
Image Sensor1280 x 800
Drop SpecificationMultiple 5 ft./1.5 m drops to concrete
Operating Temperature14°F to 122°F (-10°C to 50°C)
Light SourceLED
Storage Temperature-40°F to 158°F (-40°C to 70°C)