Ports Menu & Forms
284
Power management while connected to a port is possible only when one or
both of the following conditions are true.
The device connected to ACS is plugged into an AlterPath PM IPDU and
is configured for power management.
The device connected to ACS is a server with an IPMI controller and the
server is added to the IPMI device list.
To see the list of previously configured IPMI devices, or to add a new
IPMI device, go to Applications > IPMI Power Mgmt.
If you click “Enable power management” and click the “Add” button, the
“Add Outlet” dialog box appears, as shown in the following figure. In this
dialog box, you can specify the AlterPath PM IPDU and the outlet number(s)
into which the device is plugged.
Power Management Key
The key sequence which the authorized user(s) can use
to perform power management.
The default for IPDU power management is Ctrl+p (^p)
Allow All Users
Radio button to allow all users to perform power
management on the configured port.
Allow Users/Groups
Radio button to allow only selected users or groups to
perform power management on the configured port.
New User/Group
(available only if “Allow Users/
Groups” radio button is selected)
Entry field to add a new user/group
Allowed Users/Groups
(available only if “Allow Users/
Groups” radio button is selected)
View list box of authorized users or groups.