EasyManua.ls Logo

Cyclades AlterPath ACS - To Configure a User for IPDU Power Management While Connected to a Serial Port

Cyclades AlterPath ACS
398 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ports Menu & Forms
286
d. Enter the power management hot key in the “Power Management
Key” field.
Enter a caret (^) for the escape key, as in ^p. The caret stands for the
Ctrl key.
If you want to configure IPMI power management on this port,
continue to Step 3.
If you are done, go to Step 4.
3. To enable IPMI Power Management of an IPMI device connected to the
currently selected port, do the following steps.
This procedure assumes you have added the connected IPMI device in the
Applications > IPMI Power Mgmt. form.
a. Click the “Enable IPMI on this port” checkbox
The “IPMI key” and “IPMI Server” fields appear.
b. Enter a key in the IPMI key field.
Enter the key combination in the IPMI key field with ^, as in ^i. The
caret (^) stands for the Ctrl key.
The administrator of the device connected to this serial port uses this
hot key to bring up the IPMI power management screen.
c. Select the name of the IPMI device from the “IPMI Server” pull-
down menu.
4. Click “Done.”
5. Click “apply changes.”
T To Configure a User for IPDU Power Management While
Connected To a Serial Port
Perform this procedure to allow a user to perform power management on a
device while connected to it through one of the ACS’s serial ports.
1. Configure a serial port for IPDU power management as described in the
previous section.
2. To permit everyone to perform power management on this port, click the
“Allow All Users” radio button.

Table of Contents

Other manuals for Cyclades AlterPath ACS

Related product manuals