Isolette® Infant Incubator (Model C2000) Service Manual Page vii
Oxygen Concentration is High . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 58
Hood Does Not Tilt or Close Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 60
Controller Failure #1—EEPROM Circuitry Failure . . . . . . . . . . . . . . . . . . 2 - 63
Controller Failure #2—Ambient Air Probe Failure . . . . . . . . . . . . . . . . . . 2 - 64
Controller Failure #4—Controller Cooling Fan Failure . . . . . . . . . . . . . . . 2 - 65
Controller Failure #5—Display Test Failure . . . . . . . . . . . . . . . . . . . . . . . 2 - 66
Controller Failure #7—Power Supply Voltage Failure . . . . . . . . . . . . . . . 2 - 67
Controller Failure #8—RAM Test Failure . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 68
Controller Failure #9—Real-Time Clock Failure. . . . . . . . . . . . . . . . . . . . 2 - 69
Controller Failure #10—Watchdog Timer Failure . . . . . . . . . . . . . . . . . . . 2 - 70
Controller Failure #11—Relay Test Failure . . . . . . . . . . . . . . . . . . . . . . . 2 - 71
Controller Failure #13—Heater Circuit Failure Detected . . . . . . . . . . . . . 2 - 72
Controller Failure #14—Low Heater Current Detected. . . . . . . . . . . . . . . 2 - 73
Heater Thermocouple Does Not Work Properly . . . . . . . . . . . . . . . . . . . . 2 - 74
Humidity Heater Draws Too Much Current. . . . . . . . . . . . . . . . . . . . . . . . 2 - 76
Motor Fails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 77
Communication Between the Sensor Module and the Controller Fails . . 2 - 78
Sensor Module Is Out of Position. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 80
A Stuck Key Is Detected. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 81
Unit Fails the Non-Volatile Memory (NVM) Integrity Test. . . . . . . . . . . . . 2 - 82
Access Panel Assembly Does Not Latch Properly . . . . . . . . . . . . . . . . . . 2 - 83
Iris Entry Port Does Not Open or Close Properly . . . . . . . . . . . . . . . . . . . 2 - 85
Access Door Does Not Operate or Latch Properly. . . . . . . . . . . . . . . . . . 2 - 86
Heat Shield Does Not Latch Properly. . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 88
Mattress Tray Does Not Tilt Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 90
Mattress Tray Is Damaged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 92
Air Intake Is Not Working Properly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 94
X-ray Tray Does Not Operate Properly . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 96
Sensor Module Lock Does Not Secure the Sensor Module (Units Equipped With
the Sensor Module Lock Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 - 98
Incubator Takes Longer Than One Hour to Warm Up to the Air Set Temperature2

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Isolette C2000 and is the answer not in the manual?

Dräger Isolette C2000 Specifications

General IconGeneral
BrandDräger
ModelIsolette C2000
CategoryMedical Equipment
LanguageEnglish

Related product manuals