EasyManua.ls Logo

Hioki 8835-01 - Page 205

Hioki 8835-01
406 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
183
────────────────────────────────────────────────────
8.6 Using the Analog Trigger Function
────────────────────────────────────────────────────
NOTE
2. Set the lower and upper trigger levels.
(1) Move the flashing cursor to the position
shown in the figure on the left, and use the
function keys to set the lower trigger level.
: Value up, large step
: Value up, small step
: Value down, small step
: Value down, large step
(2) Move the flashing cursor to the position
shown in the figure on the left, and use the
JOG control or the function keys to set the
upper trigger level.
(On the DISPLAY screen, the setting cannot
be made with the
JOG control.)
The upper trigger level must not be smaller than the lower trigger level, or
the lower trigger level must not be larger than the upper trigger level.
3. Set the trigger filter
This setting cannot be made from the display
screen.
Filter width is specified using sampling
points.
(1) Move the flashing cursor to the position
shown in the figure on the left.
(2) Use the
JOG control or the function keys to
select the filter width.
In the memory recorder function
OFF: Trigger filter is disabled.
0.1 to 10.0: Trigger filter is enabled.
Filter width is specified using
divisions.
In the recorder function
: Trigger filter is disabled.
: Trigger filter is enabled.
Filter width is 10 ms.

Table of Contents

Related product manuals