iTN2100 (P100R002) Hardware Description
13 EOP cards
Raisecom Technology Co., Ltd.
99
Interface
Status
Description
LNK/ACT
(18)
Green
Link working LED
Green: the link interface is properly connected.
Off: the link interface improperly connected or
disconnected.
Blinking green: the link interface is receiving or sending
data.
13.5.5 Alarms
Table 13-24 lists alarms of the OPCOM3500E-EOP-FEE1×8.
Table 13-24 Alarms of the OPCOM3500E-EOP-FEE8
Alarm
Cause
Level
E1 AIS alarm
E1 signals are composed of "1" only, because
transmission fails or the peer device outputs AIS signals.
Minor
E1 LOF alarm
The output data of uplink devices is incorrect, because
services are improperly configured or hardware fails.
Critical
E1 CRC alarm
Data error occurs in transmission.
Critical
13.5.6 Specifications
Table 13-25 lists specifications of the OPCOM3500E-EOP-FEE1×8.
Table 13-25 Specifications of the OPCOM3500E-EOP-FEE1×8
Parameter
Value
Dimensions
25 mm (width) × 232 mm (depth) × 240 mm (height)
Weight
0.35 kg
Max. power consumption
8 W