Raisecom
iTN2100 (P100R002) Hardware Description
Raisecom Technology Co., Ltd.
6.1.3 Interfaces
Interface types
There are five interfaces on the OPCOM3500E-2STM1/4-M panel, as shown in Table 6-1.
Table 6-1 Interfaces on the OPCOM3500E-2STM1/4-M panel
Service uplink interface.
TX indicates sending and RX indicates receiving.
2 Mbit/s or 2 MHz clock synchronization input
interface. You can set it to 2 Mbit/s or 2 MHz
through software.
2 Mbit/s or 2 MHz clock synchronization output
interface. You can set it to 2 Mbit/s or 2 MHz
through software.
Interface parameters
Table 6-2 lists parameters of interfaces 1 and 2 on the OPCOM3500E-2STM1/4-M.
Table 6-2 Parameters of interfaces 1 and 2 on the OPCOM3500E-2STM1/4-M
STM-1 or STM-4, configurable
Comply with ITU-T G.707 recommendations.
Comply with ITU-T G.783 and ITU-T G.825
recommendations.
Optical interface parameters
Comply with ITU-T G.957 recommendations.
Table 6-3 lists parameters of the clock interfaces on the SYNC-RX/SYNC-TX, as listed in
Table 6-3 and Table 6-4.
Table 6-3 Parameters of 2 Mbit/s clock interface on the OPCOM3500E-2STM1/4-M
CC3 male connector (unbalanced)