Overview of configuration parameters
Administration and maintenance
A31003-K16-X001-3-7620
,
07/99
7-34
Hicom 100 E Version 2.1, Service manual
Timeout for activating feature dur-
ing call
2 s Multiples of 100 ms x
Re-seizure disable time 0 s Multiples of 1 s x
Callback timeout 5 s Multiples of 1 s x
Callback duration 20 s Multiples of 1 s x
Timeout before recall in the case of
"Transfer without notification"
30 s Multiples of 1 s x
Recall timeout after "Transfer with-
out notification" and "Park"
45 s Multiples of 1 s x
Timeout before recall in the case of
"Park"
180 s Multiples of 10 s
Timeout before recall is activated at
intercept console
60 s Multiples of 10 s x
Call forwarding timeout 6 s Multiples of 1 s x
Flash time for satellite PBX opera-
tion
90 ms Multiples of 10 ms x
Flash time for trunk operation 270 ms Multiples of 10 ms x
Dial pause 3 s Multiples of 100 ms x
Timeout, if dialling not performed 10 s Multiples of 1 s x
S
o
configuration
Extension bus short bus Default/short bus/long bus x x
Port type automatic Automatic, Euro trunk, CorNet
network, QSIG network, VN, bus
x19 3
Line monitoring yes yes/no x x
Operating mode P-P Point-to-point
point-to-multipoint (V2.0.1+)
X.31 collision processing (V2.0.1+)
x
x
x
x
x
TEI entry for PMP
(only up to SW 2.0.1+)
22 01 to 63 x x
Networking
Route parameters Name, system ext. number x 16 15
Configuration items Default Entries PC Term.
CDM
menu
Table 7-5 System configuration via PC and/or programming telephone