EasyManuals Logo

Siemens SCALANCE XR-300WG User Manual

Siemens SCALANCE XR-300WG
618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #100 background imageLoading...
Page #100 background image
The parameters have the following meaning:
Parameter Description Range of values / note
showfiles Shows the available files -
filetype Keyword for a file type to be loaded -
filetype Name of the file type max. 100 characters
Result
The file types are displayed or the file is copied.
Further notes
You configure the name of the file with the tftp filename command.
With the "show loadsave files" command, you can display the file types.
3.2.6.7 tftp server
Description
With this command, you configure the access to a TFTP server.
Requirement
You are in the LOADSAVE configuration mode.
The command prompt is as follows:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp server ipv4 <ipv4-address>[port<tcp port(1-65535)>]
The parameters have the following meaning:
Parameter Description Range of values / note
ipv4 Keyword for an IPv4 address -
ipv4-address Value for an IPv4 unicast address Enter a valid IPv4 unicast address.
port Keyword for the port of the server via
which the TFTP connection runs
-
tcp port Number of the port 1 … 65535
For information on identifiers of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Configuration
3.2 Load and Save
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
100 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents