Parameter Description Range of values / note
Type Type of the SNMP notification
Trap
Generates a trap.
Inform
Generates a log entry or sends
an entry to the log server.
Storage type Specifies whether the settings remain
following a restart.
:
The settings are lost after a
restart
:
The settings are retained after
a restart
Result
The details of the SNMP notifications are configured.
Further notes
You delete the details of an SNMP notification with the no snmp notify command.
You display the configured SNMP notifications with the show snmp notif command.
You display the configured SNMP target addresses with the show snmp targetaddr
command.
7.5.2.13 no snmp notify
Description
With this command, you delete the details of the SNMP notifications.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp notify <NotifyName>
The parameter has the following meaning:
Parameter Description Range of values / note
NotifyName Name of the notification max. 32 characters
Network protocols
7.5 SNMP
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
340 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals