Syntax
Call up the command with the following parameters:
show cabletest interface <interface-type> <interface-id>
The parameters have the following meaning:
Parameter Description Range of values / note
interface-type Type of interface Enter a valid interface.
interface-id Interface identifier
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The result is displayed.
Further notes
You enable the cable test function with the cabletest interface command in the Global
configuration mode.
12.1.3.9 show interface transceiver details
Description
This command runs error diagnostics for an SFP port.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameter assignment:
show interface transceiver details
Result
Hardware information (model, serial number) and operating parameters (data transmission
rate, voltage and current consumption as well as the transmit and receive power) for SFP port
are displayed.
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
548 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals