Syntax
Call up the command with the following parameters:
rmon collection history<index(1-52)>
[buckets<bucket-number(1-65535)>]
[interval<seconds(1-3600)>]
[owner<ownername(127)>]
The parameters have the following meaning:
Parameter Description Range of values / note
index Number of the recording 1 ... 65535
buckets Keyword for entries -
bucket-number Maximum number of entries (record‐
ings)
1 ... 65535
The maximum number of entries
can be restricted by the capacity
of the device.
Default: 50
interval Keyword for recording intervals -
seconds Duration of the recording intervals in
seconds
1 ... 3600
Default: 1800
owner User to which the event is assigned -
ownername User name of the user max. 127 characters
Default: monitor
If you do not select any parameter from the parameter list, the default values are used.
Result
The data is recorded.
Further notes
You can display the content of a recording with the show rmon history command.
12.4.3.4 no rmon collection history
Description
With this command, you end the recording of statistical data of the interface.
Requirement
You are in the Interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Diagnostics
12.4 RMON
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 585