Page #365 background image
You can display the status of this function and other information with the show ip arp
command.
7.9.2.2 no arp timeout
Description
With this command, you reset the timeout setting of the ARP cache back to the default value.
The default value for the timeout setting is 300 seconds.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no arp timeout
Result
The timeout setting for the ARP cache is reset to the default value.
Further notes
You change the timeout setting with the arp timeout command.