12.1.8.6 severity
Description
With this command, you configure the threshold values for the sending of system event
notifications.
Requirement
You are in the EVENTS Configuration mode.
The command prompt is as follows:
cli (config-events) #
Syntax
Call up the command with the following parameters:
severity { mail | log | syslog } { info | warning | critical }
The parameters have the following meaning:
Parameter Description Range of values / note
mail Specifies the threshold value for send‐
ing system event messages by e-mail.
-
log Specifies the threshold value for enter‐
ing system event messages in the log
table.
-
syslog Specifies the threshold value for enter‐
ing system event messages in the Sy‐
slog file.
-
info System events are processed as of the
severity level "Information".
-
warning System events are processed as of the
severity level "Warning".
-
critical System events are processed as of the
severity level "Critical".
-
Result
The settings for sending system event messages are configured.
The "severity" function is enabled.
Further notes
You disable the setting with the no severity command.
You display the status of this function and other information show events severity
Diagnostics
12.1 Event and fault handling
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
560 Configuration Manual, 07/2017, C79000-G8976-C361-06

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals