no standby port {<interface-type><interface-id>}
The parameters have the following meaning:
Parameter Description Range of values / note
interface-type Type or speed of the interface Enter a valid interface.
interface-id Module no. and port no. of the interface
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The ports for a standby connection are disabled.
Further notes
You enable the setting with the standby port command.
You can display the status of this function and other information with the show ring-
redundancy command.
8.4.6.10 standby wait-for-partner
Description
With this command, you enable the "Wait for standby partner" function on the device. A standby
connection is enabled only after the standby master and the standby slave as well as their
standby partners have established a connection. This ensures that the redundant connection
is really available before communication via a standby connection is enabled. As default, this
function is enabled.
Requirement
You are in the Redundancy configuration mode.
The command prompt is as follows:
cli(config-red)#
Syntax
Call the command without parameters:
standby wait-for-partner
Result
The "Wait for standby partner" function is enabled.
Layer 2 management protocols
8.4 Ring redundancy and standby connection
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface