forbidden<interface-type><0/a-b,0/c,...>
[<interface-type><0/a-b,0/c,...>]
[portchannel<a,b,c-d>]
]
[name<vlan-name>]
The parameters have the following meaning:
Parameter Description Range of values / note
interface-type Type or speed of the interface Enter a valid interface.
/a-b,0/c,... Port no. of the interface
port-channel Keyword for a port channel -
a,b,c-d Port no. of the interface Enter a valid interface name
untagged Keyword for interfaces or ports that
transfer data packets without VLAN
marking
-
all Specifies that all interfaces or ports are
set to "untagged"
-
forbidden Keyword for forbidden interfaces or
ports
-
name Keyword for the name assignment -
vlan-name Name of the VLAN max. 32 characters
For information on names of addresses and interfaces, refer to the section "Addresses and
interface names (Page 36)".
Result
The existing VLAN configuration is replaced. To add individual interfaces, you need to recreate
the full list.
Further notes
You display details of the function with the show vlan command.
You reset the settings with the no ports command.
6.1.4.4 no ports
Description
With this command you remove all ports i.e. Member Ports (M), Untagged Member Ports (U)
and Forbidden Ports (F) from a VLAN.
Requirement
You are in the VLAN configuration mode.
Network structures
6.1 VLAN
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 195