11.1.4.3 no user-account
Description
With this command, you delete a user.
Note
Default users "admin" as well as logged in users cannot be deleted.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no user-account <user-name>
The parameter has the following meaning:
Parameter Description Range of values / note
user-name User name Enter a valid user name.
Result
The user has been deleted.
Further notes
You create a user with the user-account command.
You show the created users with the show user-accounts command.
11.1.4.4 username
Description
With this command, you change the password of the factory set default user "admin".
Requirement
You are in the Global Configuration mode.
Security and authentication
11.1 User management
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
504 Configuration Manual, 07/2017, C79000-G8976-C361-06