The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
username {admin} password <passwd>
The parameters have the following meaning:
Parameter Description Range of values / note
admin User name of the default user with
read and write access to the config‐
uration data.
-
password Keyword for a password -
passwd Value for the password Enter the password.
The strength of the password depends on
the set password policy:
low: Password length: at least 6
characters
high: The password must meet the
following conditions:
Password length: at least 8
characters
at least 1 uppercase letter
at least 1 special character
at least 1 number
Result
The password is changed.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
Further notes
You show the created users with the show user-accounts command.
You can also change the passwords with the user-account command.
You display the currently valid password policy with the show password-policy command.
Security and authentication
11.1 User management
SCALANCE XB-200/XC-200/XF-200BA/XP-200/XR-300WG Command Line Interface
Configuration Manual, 07/2017, C79000-G8976-C361-06 505

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE XR-300WG and is the answer not in the manual?

Siemens SCALANCE XR-300WG Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE XR-300WG
CategorySwitch
LanguageEnglish

Related product manuals